Due to various reasons, if a sensor on the weighing scale is damaged, it needs to be replaced with a sensor of the same model

(1) Open the cover plate above the damaged sensor, use a jack to lift the scale platform, and remove the sensor ground wire.

(2) Open the junction box and disconnect the damaged sensor cable from the junction box. Pull out the cable at the sensor end. Attention: When pulling the cable, attach a lead wire through the scale body so that when replacing the new sensor, the cable can pass through the scale body and enter the junction box.

(3) Refer to the method in the second item above, thread the sensor cable through the scale body and into the junction box.

(4) Fix each core wire of the cable on the corresponding terminal post of the junction box according to the wiring diagram.

(5) Release the jack, level the weighing platform, and cover the cover plate.

(6) After replacing the sensor, the truck scale must be reset and calibrated.

(7) After the installation of the sensor, its excess cables should be tied up and placed in bundles, and should not be directly placed on the foundation ground.

(8) To ensure the consistency and interchangeability of sensors, sensor cables must not be cut off arbitrarily.

(9) During the installation and disassembly process, there should be no scratches or bumps on the sensor, and the cable should be protected.